<< Click to Display Table of Contents > Control Objects |
MultiHead classification |
SAMLight MarkDialog and SAMLight Normal Trigger Mode |
SAMLight Independent Trigger Mode and Flash Mode |
---|---|---|
Output synchronous Card-specific Control Object (OCCO): •ScWaitForInput •ScSetOutput •ScSetAnalogOutput •ScAutoCalib |
Synchronous execution on all cards when each card has arrived at that point in the job. |
Execution on all cards without any synchronisation. |
Buffer synchronous Card-specific Control Object (BCCO): •ScTimer •ScOverride •ScMotfOffset •ScWaitForTrigger •ScJump |
The BCCO is sent to each card once job preparation for all cards has arrived at its point in the job. Each card executes the BCCO without output synchronization. |
Execution on all cards without any synchronisation. |
Output synchronous Global Control Object (OGCO): •ScExecutable •Sc_RS232 •ScMotionControl |
Execution when each card has arrived at that point in the job. |
Not supported. |
Output synchronous Motion Control Object (OMCO): •ScMotionControl Type 8 & 14 |
Execution on card 0 when each card has arrived at that point in the job. Even if card 0 is not set (SetHead = 1). The job execution of all cards is paused while the OMCO is in progress. |
ScMotionControl type 14 control objects in flash mode: Execution on card 0 without any synchronisation. Other combinations are not supported. |
Table 60: MultiHead classification of the control objects and their execution in different modes