<< Click to Display Table of Contents > 

AEB-2 Manual > Board And Connectors > Analog Output And Power Supply

Analog Output And Power Supply
Previous pageReturn to chapter overviewNext page

The 16 bit analog outputs are provided as a differential signal for the X, Y and Z channels via the 10-pin connector  SV1. For operation an external +/- 15 V supply must be connected. Configuration of the channels to either +/-5 V or +/- 10 V output range is possible as is the delivery of 15 mA output current.

note

The negative signals are used for scan heads with differential inputs. When using a scan head without differential inputs the positive signals are used in respect to ground (pin 6 or 10 AGND).

When using the differential outputs signals with a scanner without differential inputs the scanning field will enlarge to the double size.

SV1

Figure 6: SV1 - 10-pin analog connector pin assignment

Pin

Name

Comments

1

AV+ (+15 V)

+15 V positive supply in respect to AGND, 100 mA max. current

Appropriate fuse for circuit protection must be provided by the external circuit.

2

+X

Positive X channel, max. 15 mA current

3

-X

Negative X channel, max. 15 mA current

4

+Y

Positive Y channel, max. 15 mA current

5

-Y

Negative Y channel, max. 15 mA current

6

AGND

Analog Ground, connected also to pin 10 of SV1

7

-Z

Negative Z channel, max. 15 mA current

8

+Z

Positive Z channel, max. 15 mA current

9

AV- (-15 V)

-15 V negative supply in respect to AGND,  50 mA max. current

Appropriate fuse for circuit protection must be provided by the external circuit.

10

AGND

Analog Ground, connected also to pin 6 of SV1

Table 1: AEB-2 10-pin connector assignment