<< Click to Display Table of Contents > Head2 - 26 pin |
![]() ![]() ![]() |
The connector HEAD2 provides the standard XY2-100 interface. The pin assignment is shown in figure below.
Type |
Name |
Pin number |
|
Figure 8: HEAD2 Connector Assignment |
---|---|---|---|---|
Output |
CLK_1+ |
pin 2 |
||
CLK_1- |
pin 1 |
|||
Sync_1+ |
pin 4 |
|||
Sync_1- |
pin 3 |
|||
X_1+ |
pin 6 |
|||
X_1- |
pin 5 |
|||
Y_1+ |
pin 8 |
|||
Y_1- |
pin 7 |
|||
Z_1+ |
pin 10 |
|||
Z_1- |
pin 9 |
|||
Input |
Stat_1+ |
pin 12 |
||
Stat_1- |
pin 11 |
|||
Ground |
GND |
pin 20, 21, 22 |
||
N.C. |
N.C. |
pin 13, 14, 15, 16, 17, 18, 19, 23, 24, 25, 26 |
Table 15: Head2 - 26 Pin Assignment
N.C.: Do not connect! Make sure that the scan head and the USC have the same ground potential, to avoid damages caused by ESD. |
---|