<< Click to Display Table of Contents > CO2 |
Figure 137: Power Map for CO2 Laser |
Unit: Watt or Percent can be used for the value. List: Edit this list to map a resulting power of laser pulse to the laser signal 1 and 2. The %Power column is divided into sixteen equidistant values from 0% to 100% whereas the %Laser1 and %Laser2 columns are editable. Linearize: Calculating power values so that the Bits increase linearly from 0 Watt to Max Watts. Check: The Check field is for measuring the laser power in % on a specific X-/Y-Position working with the edited Frequency under defined Laser1 and Laser2 signals. LaserOn: With this button the laser can be switched on and off again. X-Position: Scanhead X-Position in SAMLight unit. Y-Position: Scanhead Y-Position in SAMLight unit. Laser[%]: Laserpowert. Frequency [kHz]: Set frequency according to the pen frequency. Standby [μs]: Stand-by pulse length in µs for stand-by mode (for both signals equal). The stand-by mode can globally be set in optic settings for scanner card.
|
---|