<< Click to Display Table of Contents > 

SAMLight Manual > Pen Settings > Pen Advanced 

Pen Advanced 
Previous pageReturn to chapter overviewNext page

The following dialog appears when pressing the Advanced... button on the Mark property page.

mark_advanced

Figure 134: Pen Advanced Dialog

Head Selection: For Multiple Head applications HomeJumpStyle, Power Map and System PixelMap can be set up head independent.

HomeJumpStyle (Pen 256): Opens the Edit dialog for Pen #256 which is used for the home jump.

Power Map: The power map can be used to calibrate the laser in case the signals given to the laser and the resulting laser power do not behave linearly.

System PixelMap: The pixel map can be used to calibrate the laser in case the signals given to the laser and the resulting pixel occurrence do not behave linearly.

Special Laser Parameters: For some laser types (not visible if not available), pre-definition of values for special parameters like pulse length or APD index is possible.