Head ID Selection
Previous pageReturn to chapter overviewNext page

In MultiHead mode, there is a Head ID drop-down list on the EntityInfo property page to assign the selected entity to the cards.

Head ID of entities

Auto

Automatic card assignment of entities by MultiHead AutoSplit.

All

Entities are marked on all cards.

Head#

Manual card assignment of entities to the chosen card.

Table 61: Head ID of entities

Head ID specialities of Control Objects:

Groups containing control objects must always be set to Head ID Auto or All. Groups with Head ID Head# that contain control objects are not supported.

There is no All in the Head ID drop-down list for all control objects. Auto executes OCCO and BCCO on all cards.

There is no Head ID drop-down list for ScAutoCalib, ScOverride, OGCO and OMCO. The card assignment of ScAutoCalib control objects is defined via the Card ID parameter.