<< Click to Display Table of Contents > 

USC-2 Manual > Stand-Alone (Flash) Functionality > Operation Modes > Flash Job IO Selection

Flash Job IO Selection
Previous pageReturn to chapter overviewNext page

The Flash JobIOSelect mode allows to manage the selection of jobs and the start marking event via the USC-2 I/O ports without the need of a RS-232 connection.

Flash JobIOSelect inputs

Input pins

Binary Job Selection

OptoIn_2..5 or DigiIn_0..7 [a]

External Trigger

OptoIn_0

External Stop

OptoIn_1

Table 20: USC-2 Job IO Selection inputs

[a]: The JOB_SELECT_IO_EXT flag of the FM command determines if OptoIn_2..5 (up to 15 jobs) or DigiIn_0..7 (up to 255 jobs) are used as binary job selection input pins.

Flash JobIOSelect outputs

Output pins

Mark In Progress

OptoOut_0

Ready For Trigger

OptoOut_3 [a]

Job Loaded

OptoOut_4 [a]

Table 21: USC-2 Job IO Selection outputs

[a]: The SYNC command allows changing the output pins for Ready For Trigger and Job Loaded.

By default, there is the timing as shown in figure below.

timing

Figure 28: Job IO Selection timing diagram

The job select bits OptoIn_2 to OptoIn_5 have the following encodation:

OptoIn_2

OptoIn_3

OptoIn_4

OptoIn_5

Job number

0

0

0

0

Empty job

1

0

0

0

1

0

1

0

0

2

1

1

0

0

3

0

0

1

0

4

1

0

1

0

5

0

1

1

0

6

1

1

1

0

7

0

0

0

1

8

1

0

0

1

9

0

1

0

1

10

1

1

0

1

11

0

0

1

1

12

1

0

1

1

13

0

1

1

1

14

1

1

1

1

15

Table 22: Binary Job Selection in JobIOSelect mode

The Job selection bits must be valid during the complete mark. As soon as a new combination is applied the current running job will be interrupted and the new job - if valid - will be loaded.

Additional JobIO Modes:

JobIOSelectExt: Enables the selection of 255 jobs with the Extension connector of the USC-2. DigiIn_0 - DigiIn_7 have to be used.

JobIOSelectInt: A pre-defined job will be selected after boot, for configuration see FlashMode.

Please read here for important information on the JobIOSelect mode in Flash mode:

1.If trying to start marking via start trigger (OptoIn_0) when no Job has been selected or the Job Selection is not valid, nothing will happen.

2.If a Job is selected with the binary job selection pins it is not possible to leave JobIOSelect mode and it is not possible to change the FlashMode.

3.If the command SVG is sent the FM status will be saved and remain even after re-powering the USC-2 card.