<< Click to Display Table of Contents > USC Position Transformation |
Depending on the scanner controller card and marking mode (SAMLight or standalone) the coordinates stored in SAMLight job file (*.sjf) or standalone job file (*.unf) are transformed like shown in table 75.
Vector transformation |
USC-1 SAMLight |
USC-2 SAMLight |
USC-2 Flash [OF] |
USC-3 SAMLight |
USC-3 Flash [OF] |
Settings paths and flash notes |
|
---|---|---|---|---|---|---|---|
P C |
|
SJF |
SJF |
SJF |
SJF |
SJF |
SAMLight: Coordinates saved in SAMLight job file (*.sjf) |
CCI ScOpticMatrix |
SAMLight Client Control Interface (CCI) ScOpticMatrix, adjustable by CCI commands ScOpticMatrixTranslate, ScOpticMatrixRotate, ScOpticMatrixScale and ScOpticMatrixReset |
||||||
3D Surface mapping |
3D surface toolbar |
||||||
SAMLight |
Settings → Optic. Factor = (216 - 1) bit / FieldSize [mm] |
||||||
PC Z bit value |
Settings → Optic → Advanced → Correction → Z Correction Pen Settings → Misc → Defocus [mm] |
||||||
U S C |
|
|
|
UNF |
|
UNF |
Flash: Coordinates saved in flash job file (*.unf). SAMLight lens settings are used for UNF generation. |
Flash: Standalone only, not used in SAMLight, not accessible via SAMLight. Available Flash Control Interface commands: SC, RT , TRB. Order: rotation, gain, offset, sl_invert, sl_flip. Flip and invert states of the SAMLight lens settings are moved into the flash global matrix when the UNF job is generated. |
|||||||
Settings → Optic → Advanced → Correction Flash: Available Flash Control Interface commands: TRH Order: sl_flip, sl_invert, gain, rotation, offset, sl_invert, sl_flip Matrix in Info View: M##_0/1 |
|||||||
MOTF [OM] AnalogIn [AI] Wobble |
Settings → Optic → Advanced → Marking on the Fly Settings → Optic → Advanced → Analog In Pen settings → Scanner → Wobble |
||||||
USC Z bit value |
Settings → Optic → Advanced → Correction → Z Correction Pen Settings → Misc → Defocus [mm] |
||||||
Settings → Optic → Advanced → Correction Z value of *.ucf: please refer to [ZV] |
|||||||
FlatLense Defocus [3FL] |
Pen Settings → Misc → Defocus [216 bit / FieldSize] Add a static value on z output Positions in Info View: X/Y/ZCorrectedHead0/1 |
||||||
|
XY2-100 signals to scan head |
|
Table 75: Vector transformations
[OF]: |
Option Flash required. |
---|---|
[O3]: |
Option Optic3D required. Optic3D is not possible with USC-2 and standalone mode. |
[OM]: |
Option MOTF required. |
[AI]: |
AnalogIn is only available for USC-2 / USC-3. |
[ZV]: |
Option FlatLense: Z bit values from UCF file are used. Option Optic3D (+ FlatLense): Z bit values from UCF file are ignored. |
[3FL]: |
Option FlatLense required, if Optic3D license is used, the defocus value is included in Z bit value calculation. |