<< Click to Display Table of Contents > 

SAMLight Manual > Mark > Mark Dialog > Red pointer

Red pointer
Previous pageReturn to chapter overviewNext page

Start Pointer: Starts the red pointer. This button is active only if the red pointer is enabled. For the red pointer pen #255 is used (see chapter Mark Settings). While the red pointer is outlining, scale and nudge can be done with the short keys listed below.

Ctrl + arrow key: Nudge

Ctrl + arrow key: 5 * Nudge

Alt + up/down arrow key: Scale

Shift + Alt+ up/down arrow key: 5 * Scale

note

Nudge Step and Scale Factor can be defined within Settings → System → View.

The StopKey in Settings → System → Short Keys should be set to ESC/Space.

Enable: Enables the red pointer.

Individual Outline: If checked each individual outline of the objects is drawn.

Total Outline: If checked the complete outline of all objects will be drawn by the red pointer, otherwise only the outline of one object will be drawn.

Individual Border: If checked, the red pointer draws the real geometry of the object.

Outermost Border: If checked, the red pointer draws the outermost individual borders of objects.

Red pointer Entities: If checked, only red pointer entity checked object(s) will be drawn. An object can be checked as red pointer entity in the entity list window.

Advanced: The following dialog opens after clicking on the Advanced button.

mark_dialog_advanced

Figure 319: Mark Advanced Dialog

Auto Pointer: If enabled, the red pointer starts automatically after each marking showing the red pointer shape of the next marking sequence.

SwitchOffDuringMark: If enabled, the red pointer is switched off during mark.

Delay: Value determines delay of the red pointer. This value will overwrite the delay values (jump, mark and poly delay) in pen 255 (red pointer pen).

Speed: Value determines speed of the red pointer. This value will overwrite the speed values (mark and jump speed) in pen 255 (red pointer pen).

Defocus: This activates a focus shift on the Z-Axis.

In case 'char based splitting' : If enabled, the height of the whole string is taken for outlining with the Red Pointer. See example in Fig.320:

TakeWholeStringHeight

Figure 320: Green for flag disabled, blue for flag activated.

Execute first motion in job or in selected job items before normal red pointer: If enabled, the first ScMotionControl entity of the job will be executed when the Red Pointer start button is pressed.

Split Red Pointer repetitions: Can be checked only if entity is a split entity. You can set for first, middle and last split parts in between a red pointer repetition count. If unchecked (default), the red pointer runs endless on first split part. If the entity is not a split entity, this option is deactivated. This settings are necessary for the correct Red pointer function int he splitting mode.

note

Split Red Pointer repetitions settings are necessary for the correct Red pointer functionality in the splitting mode.