Laser type 0, version 0, IPG
Figure 40: Timing diagram of default IPG laser signals
•Opto_Out_0 is the marking in progress (MIP) signal which is activated at the start of the job and closed at the end of the job.
•Laser_Gate is activated at the beginning of the vector marking.
•The power is set on 8-bit digital laser port (depending on the power of the pen, the Power Map and the overwrite parameter) with a minimum delay of the job execution delay (JED).
•Starting with Laser_Gate, the frequency and pulse length of the selected pen is activated for the Laser_A signal. For inactive Laser_Gate signal, the standby frequency is taken for Laser_A with the standby pulse length (if enabled).
•LP0 gives a latch signal for changes in the power (pen settings).