CO2 laser
Previous pageReturn to chapter overviewNext page

0Laser type 0, version 0, CO2

DefaultCO2laserSignals

Figure 37: Timing diagram of default CO2 laser signals

Opto_Out_0 is the marking in progress (MIP) signal which is activated at the start of the job and closed at the end of the job.

The Laser_Gate signal is activated with a minimum delay of the job execution delay (JED).

The pen frequency is used for Laser_A. The power (PWM, duty cycle) of the selected pen is set via the pulse length of Laser_A (according to the power in % which is set in the pen, the Power Map and the overwrite parameter).

For inactive Laser_Gate signal, the standby frequency is taken for Laser_A with the standby pulse length (if enabled).