Disable Message Beep

Set

Get

DLL Function,

int CCI_Return = ScSetLongValue(int Value_Type, int Beep_State)

int Beep_State = ScGetLongValue(int Value_Type)

ASCII Function

int CCI_Return = ScCciSetLongValue(int Value_Type, int Beep_State)

int Beep_State = ScCciGetLongValue(int Value_Type)

Description

Disable the message beep in SAMLight.

Value_Type

Type: int

ID:

Location: ScComSAMLightClientCtrlValueTypes

scComSAMLightClientCtrlLongValueTypeDisableMessageBeep

143

Beep_State

Type: int

Unit: none

0: Enable message beep.

1: Disable message beep.

CCI_Return

Type: int

CCI error number, see error list.

Notes

-

C# Example: Disable message beep:

 

int CCI_Return = cci.ScSetLongValue( ( int )ScComSAMLightClientCtrlValueTypes.scComSAMLightClientCtrlLongValueTypeDisableMessageBeep, 1);

C# Example: Get message beep state:

 

int State = cci.ScGetLongValue((int)ScComSAMLightClientCtrlValueTypes.scComSAMLightClientCtrlLongValueTypeDisableMessageBeep);

Table 338: Disable Message Beep